Access & Safety

Etapes à suivre pour organiser des visites professionnelles dans les installations faisceaux
http://be-safety.web.cern.ch/content/procedure-visitors Edms 1281098 + 1137263
http://be-safety.web.cern.ch/content/access-conditions-workers
Guidelines applicable to the Press Service to organise visits in Beam Facilities EDMS 1530464

SIR

Access to Complex PS
Safety Information Registration Information https://sir.cern.ch/

CERN Safety Introduction
CERN Beam Facilities
Electrical Safety Awareness
Radiation Protection - Supervised Area

EDH

https://edh.cern.ch/

EPI

Safety shoes
Helmet plus Light
Electronic dosimetre
Passive dosimetre.

IMPACT

IMPACT - Fundamentals All interventions in the PS&TT2 have been declared using Impact https://impact.cern.ch/impact/ - Private e-groups not allowed

Automated RP dose registration
Overview and tracking of activities
Used as planning tool for EN-MEF and RP for work optimisation
Only approved activities take place
Additional filter for access

Technical Stops & Shutdown periods

Operation period

All interventions in the PS and TT2 have been declared in IMPACT

Access Requests https://op-webtools.web.cern.ch/op-webtools/Access/index.php
+  IMPACT made by team (or person) requesting

 

Piquet Impact
“In progress” during the run, “Interrupted” during technical stops

IMPACT under responsibility of groups concerned (with support of OP and RP)

PS-TT2-IT-CS-STD-RUN-2015
PS-TT2-TE-ABT-STD-RUN-2015
PS-TT2-TE-CRG-STD-RUN-2015….

 

ADAMS

You can control the validity of your access authorizations on https://www.cern.ch/adams
Please note that the medical service no longer contact you when your medical is about to expire!!!!!!! You will receive an e-mail 2 months before informing you that some of your access rights will soon expire. It is up to you to contact the medical service to arrange a medical.

Safety Rules Regulations HSE

Guidelines applicable to the Press Service to organise visits in Beam Facilities EDMS 1530464

Safety File EDMS 1167044, 1172545, 1390058, 1543066
Reference is the EDMS 1155899 «Working on the CERN site»
Quality Procedure for Safety Documentation  Edms 1177755
Plan de coordination des travaux Edms 1271859
PS-CSAP Complex Safety Advisory Panel Website
PS main ring Safety Folder - EDMS 1167045 & EDMS 1172545
Fire detection system
Evacuation plan
CERN Proton Synchrotron Safety Review - EDMS 1119511
Consignations
: It is the responsibility of the Equipment owner to consign any equipment that they will be working on.
"Access in LINAC2, PSB, PS and TT2 During the Hardware Commissioning and Tests"1371388 CPS-Y-PRD-0001
Procédure en cas d'alarme sur une porte du CPS EDMS1286886
Blind Access SR3 procedure

TSO EN https://espace.cern.ch/en-dep-safety-office/SitePages/Home.aspx
Mandat https://edms.cern.ch/ui/file/1403715/LAST_RELEASED/GSI-SO-2_F.pdf

 

Radiation Protection PS Complex

PS information portail
RAMSES
PS_Ring Radiation Survey Results

Radiation Protection guidelines for TS, YETS & EYETS PS complex EDMS1560761

 



Training

Zone Contrôlée: https://cern.ch/safety-training/

Zone Surveillée, TREC: http://sir.cern.ch

Dosimétrie

http://cern.ch/service-rp-dosimetry ou 72155

DMC, guide de l’utilisateur: EDMS 1264719

Utilisateur occasionnels: optez pour le DMC en mode « Pool » !

Classifications RP

RAISIN: http://cern.ch/raisin

ALARA

IMPACT: http://impact.cern.ch/

WDP: http://cern.ch/rp-wdp/

Photos, videos! Layout database, Videos 360°

Risque contamination

Aspirateurs: http://cern.ch/rp-vacuum-cleaners

HFM, guide de l’utilisateur: EDMS 1329424

Travaux sur ventilation à risque radiologiques: EDMS 1296356

Déchets

CADRA! EDMS 1364231

Rejets d’eau

Service portal: water release request

Traçabilité

TREC: http://trec.cern.ch/

RP surveys,  infos, contacts, etc….

RP info Meyrin, CTF & PS complex: http://cern.ch/rp-ps ou 72504

RP info Prévessin, SPS & LHC complexes: http://cern.ch/rp-lhc/ ou 75252

Vacuum cleaner management
 
  • REQUEST
  • PROVISION
    • Provision in Buffer Zone (or B.574 or delivery in the Radiation Area)
    • Automatic email confirmation
  • USE
    • Before use declare use in TREC
    • The user is responsible of the vacuum cleaner
  • RETURN
    • Return in Buffer Zone mandatory
    • Declare the end of use (emptying request) in TREC
 

You are here